{"product_id":"pure-filters-classic-tap","title":"Pure Filters Classic Tap – Under-Sink Filtration Kit with 2-Way Mixer","description":"\u003ch1\u003e\u003cstrong\u003ePure Filters Classic Tap – Under-Sink Filtration Kit\u003c\/strong\u003e\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePure Filters Classic Tap\u003c\/strong\u003e is an under-sink filtration kit that purifies water directly at the tap. It pairs a \u003cstrong\u003epremium 2-way mixer\u003c\/strong\u003e manufactured in Spain by TRES with a \u003cstrong\u003e\u003ca href=\"\/en\/products\/filtre-coldstream-max-cf1082w-anciennement-cf521w\"\u003eColdstream CTO MAX cartridge\u003c\/a\u003e\u003c\/strong\u003e in ceramic and activated carbon, independently laboratory tested to NSF\/ANSI 42, 53 and P231 protocols. A simple, durable solution — no electricity, no tank.\u003c\/p\u003e\n\n\u003ch3\u003eWhy choose the Pure Filters Classic Tap?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiltered water directly at the tap, no jug or tank needed\u003c\/li\u003e\n\u003cli\u003eSeparate controls for mains water and filtered water\u003c\/li\u003e\n\u003cli\u003eFiltered water circuit supplied with cold water only (cartridge is protected)\u003c\/li\u003e\n\u003cli\u003eBroad-spectrum filtration documented by independent laboratory testing\u003c\/li\u003e\n\u003cli\u003e100% European quality: TRES mixer (Spain) + Coldstream cartridge (United Kingdom)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTRES mixer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eType\u003c\/strong\u003e : kitchen 2-way mixer (mains + filtered water)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e : chrome\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSpout\u003c\/strong\u003e : 360° swivel\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e : G3\/8 flexible hoses\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e : low-lead brass\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e : EN 817 (PN10), EN 248, Positive Lists 4MS, ISO 9001:2015\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReference\u003c\/strong\u003e : TRES 23045402\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFiltration performance (Coldstream CTO MAX CF1082W cartridge)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e : high-density ceramic + compact activated carbon\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRecommended capacity\u003c\/strong\u003e : 5,000 litres\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReplacement\u003c\/strong\u003e : every 6 months\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e : 2.5 L\/min\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating pressure\u003c\/strong\u003e : 0.6 to 8.6 bar\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e : 5°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTesting\u003c\/strong\u003e : NSF\/ANSI 42, 53 and P231 protocols (ISO 17025 accredited laboratory)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eContaminants removed\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMicro-organisms\u003c\/strong\u003e : bacteria, viruses, cysts\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeavy metals\u003c\/strong\u003e : lead and others\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFine particles\u003c\/strong\u003e : microplastics\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eChlorine and chloramines\u003c\/strong\u003e : tastes and odours\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eChlorination by-products\u003c\/strong\u003e : THMs, HAAs\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePesticides and herbicides\u003c\/strong\u003e : broad spectrum\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePFAS\u003c\/strong\u003e : forever chemicals\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePharmaceutical residues and hormones\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePack contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Pure Filters Tap Classic by TRES mixer (ref. TRES 23045402)\u003c\/li\u003e\n\u003cli\u003e1 under-sink filter housing with connection kit\u003c\/li\u003e\n\u003cli\u003e1 Coldstream CTO MAX cartridge CF1082W (formerly CF521W)\u003c\/li\u003e\n\u003cli\u003e1 filter housing wrench\u003c\/li\u003e\n\u003cli\u003eInstallation and user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eThe Pure Filters Classic Tap requires installation by a qualified plumber to ensure compliant, leak-free mounting. The filtered water circuit is connected as a branch on the cold water inlet only. On first use, run filtered water for 5 minutes (a slight carbon deposit at start-up is normal).\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReplace the cartridge every 6 months\u003c\/li\u003e\n\u003cli\u003eClean the mixer with gentle products\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pure Filters","offers":[{"title":"Default Title","offer_id":54008170512726,"sku":"PFCT-M2","price":599.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1022\/5319\/9702\/files\/pure-filters-tap-classic.webp?v=1779884873","url":"https:\/\/pure-filters.nl\/en\/products\/pure-filters-classic-tap","provider":"Pure Filters","version":"1.0","type":"link"}